FY22 GetGo OSHA Safety Audit

Location 3641 - Bridgeville GetGo/WetGo Fuel Station
3029 Washington Pike
Bridgeville, PA 15017
(412) 220-7190
Record Keeping and Mandatory Posting
Is the Job Safety & Health Protection ("It's the Law") poster displayed as required? Yes
Photo
Does Leadership understand the process for reporting incidents that result in death or in one or more hospitalizations, an amputation or loss of an eye properly reported? Yes
Photo
GetGo Safety Manual
Does Store Leadership know how to access the GetGo Safety Manual? Yes
Photo
Safety Activities
Is the Monthly Safety Inspection completed and documented? No
Photo
No monthly inspection completed for December 2020. Previous 12 periods have been checked.
Is the Safety action based checklist completed each month? No
Photo
Store completed P4 activities for November instead of P5. Store completed the same activities from the previous period. Period 5 documents were printed to complete.
Are safety discussion topics reviewed with Team Members monthly? No
Photo
Store completed P4 safety discussion points again for November P5. Discussion points are incorrect. Store should’ve completed FY22 P5. period 5 documents were printed to complete during visit.
OSHA/Safety Training
Is OSHA/Safety First elearning training conducted and documented annually? Yes
Photo
Is the current ABC operator training completed? Yes
Photo
Bloodborne Pathogen Program
Are Blood & Bodily Fluid Clean-up kits along with personal protective equipment available at each first aid kit? Yes
Photo
Does store leadership understand the process for bloodborne pathogen post exposure evaluation and follow-up? Yes
Photo
First Aid and CPR
Does store have adequate number of designated and certified, First Aid and CPR Responders? Yes
Photo
Are adequately stocked first aid kits accessible to first Responders? Yes
Photo
Are plumbed/bottle eyewash stations readily accessible and in good operating condition? No
Photo
Eyewash station expired in carwash. Store needs to have eyewash replaced. Please submit work order.
Hazard Communication Program
Is yearly survey of chemicals conducted, properly documented and available to Team Members? Yes
Photo
Are Material Safety Data Sheets SDS available for all chemicals that Team Members use? Yes
Photo
Do Team Members know where to access SDS? Yes
Photo
Are all chemical containers properly labeled? Yes
Photo
Lockout/Tagout Program
Is the annual Hazardous Energy Survey conducted and properly documented? Yes
Photo
Are the appropriate lockout/tagout devices and tags available? Yes
Photo
Do Team Members exercise the necessary precautions when cleaning/servicing cord and plug equipment? Yes
Photo
Lifting/Ergonomics
Is product stored according to height and weight requirements? Yes
Photo
Do team members understand safe lifting practices? Yes
Photo
Electrical
Are all electrical panels and disconnects easily accessible? Yes
Photo
Are extension cords used properly? Yes
Photo
Personal Protective Equipment (PPE)
Is an annual assessment of hazards and required Personal Protective Equipment (PPE) conducted and documented? Yes
Photo
Is PPE provided, clean, accessible, and properly maintained? Yes
Photo
Are team members properly using cut resistant gloves? Yes
Photo
Are all fresh department team members wearing slip resistant shoes/covers? Yes
Photo
Are proper procedures followed for lot work? Yes
Photo
Are safety cutters used properly? No
Photo
Two leaders explained they use the blade on the safety cutter to cut tape on boxes. Leaders were coached on the tape splitter and the film cutter, using only the blade for cardboard. Another TM on the floor holding cardboard box in arms against body while using blade to cut box open. TM stopped and coached.
Are puncture resistant gloves worn when emptying customer facing trash? No
Photo
TM outside with trash cart, plastic bags and vest on going to empty out WetGo vacuum trash without puncture resistant gloves. TM was stopped and told to get required PPE, puncture gloves to empty customer trash.
Do Team Members use correct PPE when using a pressure washer or car wash chemicals? (N/A if not a car wash) No
Photo
Store is using shoe covers instead of the WetGo boot covers that are for the WetGo. Please order the slip resistant boots for the WetGo. Store ordered during visit.
Slip/Trip - Floor Surface
Are cones and similar devices which are used for warning or barricading an area readily available per department? Do TMs know where these devices are located and when they are to use them? Yes
Photo
Are floor mats used properly? No
Photo
PIG mat missing from slushy area. Please install.
Are all ladders and stop stools in good condition, stored out of the path of travel, and are ladders secured to prevent falling? Yes
Photo
Do Team Members understand the proper steps for cleaning spill and slip hazards? Yes
Photo
Are spill absorbent stations in good condition with absorbent material in container (at least 1/3 full)? Yes
Photo
Emergency Preparedness & Response
Is the EMS Manual completed and available? No
Photo
EMS manual has not been updated with the current district leadership contact information. Please update the noted areas in the EMS manual with DL Zee.
Are all Team Members aware of their assigned duties as outlined in the Emergency Management System Manual? Yes
Photo
Is the emergency action diagram of the store including emergency exits, fire extinguishers, spill absorbent stations, and tornado gathering points posted? Yes
Photo
Did the store complete an emergency evacuation plan for any TMs that have Self-Identified disability? N/A
Photo
Do TMs know the location of the main gas shut-offs, electrical shutoffs, and fuel shut-offs? Yes
Photo
Are all emergency exits: clearly marked, free of obstructions, unlocked, lighted and visible? Yes
Photo
Are all combustible materials at least 3 feet from heat sources? Yes
Photo
Are storage requirements for Blue Rhino Propane displays/cages in place? Yes
Photo
Are all compressed gas cylinders secured, located out of path of travel, and not near an exit? Yes
Photo
Is the fixed fire extinguisher system for fryers ready for operation? No
Photo
Two leaders in the kitchen did not know that the activation pull handle is for the fryer system. Both leaders were coached on the ansul pull handle. TMs thought it was a fire alarm for the store.
Are all fire extinguishers mounted securely, equipped with a current inspection tag, and checked monthly? Yes
Photo
Extinguishers annual inspection tag was replaced in November 2021.
Is the proper spill response kit available and accessible along with the proper PPE? No
Photo
Store has pump, cob, dust pan and broom, and drums. Store does not have pry bar, clamp, funnel, or 2.5 gallon bucket with lid. Store to order off of Ge marketplace.
Does Store Leadership understand their role and responsibility during the use of "Hot Work Permit" kits? Yes
Photo
Additional Comments / Observations?
- Chemical spill in the WetGo backroom. Environmental was contacted and explained how to clean up spill.

- WetGo backroom light is out. Store entered WO.

- TM asked for a kneeling pad. Leader told to order more through GEmartketplace.
FY22 GetGo OSHA Safety Audit Score 78.26